Last edited by Jusar
Thursday, July 16, 2020 | History

3 edition of Use of iron salts for control of activated sludge bulking, caused by Sphaerotilus found in the catalog.

Use of iron salts for control of activated sludge bulking, caused by Sphaerotilus

John T. Pfeffer

Use of iron salts for control of activated sludge bulking, caused by Sphaerotilus

final report, project no. S-059-ILL.

by John T. Pfeffer

  • 107 Want to read
  • 16 Currently reading

Published by University of Illinois, Water Resources Center in Urbana .
Written in English

    Subjects:
  • Sewage -- Purification -- Activated sludge process.,
  • Iron salts.,
  • Sphaerotilus.,
  • Sludge bulking.

  • Edition Notes

    StatementJohn T. Pfeffer and Yueh Chang.
    SeriesWRC research report : no. 127, Series.
    ContributionsChang, Yueh, joint author.
    Classifications
    LC ClassificationsHD1694 .A136 no. 127, TD756 .A136 no. 127
    The Physical Object
    Pagination87 p. :
    Number of Pages87
    ID Numbers
    Open LibraryOL4377507M
    LC Control Number78621275

    Chudoba J, Ottova V, Madera V ( a) Control of activated sludge filamentous bulking: I. Effect of the hydraulic regime or degree of mixing in an aeration tank. Wat Res – CrossRef Google Scholar. Notes on Activated Sludge Process Control was started in the spring of by the DEP’s Operation and Maintenance Division to served as a training resource for JETCC and during (g)(1) on-site training.

    Industrial wastewater treatment describes the processes used for treating wastewater that is produced by industries as an undesirable by-product. After treatment, the treated industrial wastewater (or effluent) may be reused or released to a sanitary sewer or to a surface water in the environment.. Most industries produce some trends have been to minimize . When bulking of activated sludge is caused by overloading, prechlorination to reduce the load on the aeration process has been tried with some success. Prechlorination of the primary tank influent to produce a residual of about mg/L in the primary tank effluent is used.

    ACTIVATED SLUDGE PROCESS TABLE OF CONTENTS (Continued) Topic Page Physical Arrangements of the Process Complete Mix Activated Sludge Plug-Flow Activated Sludge Activated Sludge with Sludge Reaeration SECTION IV-LABORATORY CONTROL INTRODUCTION IV-1 LABORATORY SAMPLING AND . Vol. 8, No. 2 USE OF CHLORINE FOR CORRECTION OF SLUDGE BULKING after definite intervals of time to observe the effect of the chemicals on the fungus strands, as well as upon the other forms of plankton. Phenol, lime, copper sulphate, iron salts, alum, sulphur, silica gel, activated carbon, sodium sulphite and chlorine were among the chemi.


Share this book
You might also like
Moving out of poverty

Moving out of poverty

The new you

The new you

Doras eggs

Doras eggs

Out of the shadows

Out of the shadows

UFOs

UFOs

Automation

Automation

Peasant life in China

Peasant life in China

bar-tenders guide

bar-tenders guide

Admissions of states to the United Nations

Admissions of states to the United Nations

Pieces of the Heart

Pieces of the Heart

The Wendy Hazen Poster Calendar for the Year 2006

The Wendy Hazen Poster Calendar for the Year 2006

Exploring technology

Exploring technology

The Other Family (Rhvp-Remainder Ser.)

The Other Family (Rhvp-Remainder Ser.)

Biomarkers & Risk Assessment

Biomarkers & Risk Assessment

Use of iron salts for control of activated sludge bulking, caused by Sphaerotilus by John T. Pfeffer Download PDF EPUB FB2

Other nutrients such as iron or sulfur have been reported as limiting to activated sludge, but this is not common. Signs of nutrient deficiency include: filamentous bulking (see Table 1); a viscous activated sludge which exhibits significant exopolysaccharide ("slime") when "stained" with India ink; and foam on the aeration basin which contains.

Use of iron salts for control of activated sludge bulking, caused by Sphaerotilus. Urbana: University of Illinois, Water Resources Center, (OCoLC) Material Type: Government publication, State or province government publication: Document Type: Book: All Authors / Contributors: John T Pfeffer; Yueh Chang.

Control of the growth of this organism will help to eliminate sludge bulking as an operating problem in many activated sludge systems. Iron has been identified in the literature as a possible inhibitor to the growth of this bacterium.

However, Author: John T. Pfeffer, Yueh Chang. Controlling Activated Sludge Bulking & Foaming: From Theory to Practice Metal Salt Addition CAUTION: Do not over-dose Metal Salt Addition Aeration Basin –Manual on the Causes and Control of Activated Sludge Bulking and Foaming by Jenkins, Richard & Daigger, 3rd EditionAuthor: Eric Lynne, Bill Marten.

Abstract Iron salts are often used in activated sludge treatment plants as coagulants or to improve reactor performance. Previous studies have indicated that iron itself has an impact on the activated sludge process.

However, the interaction of iron with nitrite or nitrate present in the sludge has received little by: Tables Number 1 Page Causes and effects of activated sludge separation problems 2 2 Dominant filament types as indicators of conditions causing bulking • 12 3 Bulking filamentous microoganisms that have been controlled by chlorination 25 4 Use of hydrogen peroxide for bulking control 26 5 Subjective scoring of filament abundance 41 6.

As a sewage and industrial wastewater treatment, it makes use of air and a biological floc composed of bacteria and protozoa. The idea in controlling activated sludge is to keep the wastewater biomass-to-food ratio in balance.

To control activated sludge, you need to "have a handle" either on aeration, sludge-wasting or return-sludge flow. Activated Sludge Replacing RBC Plant Average Flow mgd Receiving Primarily Domestic Wastewater BNR Activated Sludge Three 2-Pass Reactors ~ Plug Flow, Non-Foam Trapping Future: Combination Anaerobic/Anoxic Selector Zones State of Art Secondary Clarifiers Flow Paced RAS Pumping Case 2: Marquette, MI WWTP.

activated sludge floc respire using nitrate in place of free oxygen when it is lacking and release nitrogen gas as a by-product. This gas is only slightly soluble in water and small nitrogen gas bubbles form in the activated sludge and cause sludge blanket flotation in the final clarifier.

The idea of using iron salts to control sludge bulking was further considered by Pfeffer () and substantiated by other researchers (Carter and Mckinney, ; Rensink, ).

Chang et al. () surveyed the inhibitory effect of selected iron compounds on Sphaerotilus. R.J. Foot, M.S. Robinson, in Handbook of Water and Wastewater Microbiology, Activated sludge bulking.

When the activated sludge process was first developed in the sludge was described by Arden as ‘flocculent in character’, indicating. Bulking is caused usually by hydrogen peroxide), weighting and flocculating agents (salts of iron D., Richard, M. & Daigger, G. Manual on the causes and control of activated sludge bulking.

organisms observed in Activated Sludge (Reference 4) 32 8. Dominant Flament Types Indicative of Activated Sludge Opera-tional Problems (Reference 10) 34 9. Case Examples of "Curing" Bulking by a Change in Operation Suggested by Filament Identification (Reference 4) 35 Control Measures for Activated Sludge Bulking (Reference 2) •Short Term Control Methods •Long Term Control Methods Based on the methods in the 3rd Edition Manual on the Causes and Control of Activated Sludge Bulking, Foaming, and other Solids Separations Problems and a presentation from Dr.

Michael Richard entitled “Activated Sludge Microbiology Problems and Their Control”. Approximately activated sludge samples, mostly derived from purification plants with bulking sludge, have been investigated for the presence of filamentous organisms. Improving the sedimentation properties of the activated sludge and in consequence, reducing the bulking phenomenon, may be achieved by using chemical oxidants (ozone, sodium hypochlorite, hydrogen.

Bulking has been the scourge of activated sludge ever since flow-through systems began being used in the s. It can be caused either by production of slime or growth of filamentous organisms.

Condition 9 - Slime Bulking Slime bulking (Jenkins, et al., ) is usually caused by a nutrient deficiency. As in Condition. In the activated sludge treatment system, bacteria may occur singly, or in small chains or clumps. Shifts in the activated sludge environment such as changes in pH, dissolved oxygen, nutrients etc.

will often cause a change in the behavior of the bacteria. In stead of single cells, small chains or clumps, the bacteria will begin to form longer. water. When alumina and iron coagulants are used for coagulation and clarification of surface water, mainly alumina and iron sludge are produced.

This paper describes possible alumina recovery in the water treatment procedure and re-use of sludge for treatment of municipal wastewater. The sludge can be also used for production of cement. Lecane inermis rotifers were shown to diminish sludge bulking due to their ability to ingest the filamentous bacteria in activated sludge.

To determine if rotifers are also able to control branched actinomycetes, we investigated three other Lecane species (Monogononta). In a week-long experiment, only Lecane tenuiseta significantly reduced the density of Microthrix.

Bulking Sludge is a major problem that can cause serious operational issues to the management of wastewater treatment plant. Basically with this condition around, it will be very difficult in order to get a good separation of sludge and water and this will lead to carry over of solids to the discharge side and clog up the final polishing filter.You can write a book review and share your experiences.

Other readers will always be interested in your opinion of the books you've read. Whether you've loved the book or not, if you give your honest and detailed thoughts then people will find new books that are right for them.An activated sludge that settles poorly because of flow with low bulk density.

A genius of bacteria that occurs as filaments having a sheath of deposit iron. Cause color, odor, and objectionable tastes. Demineralization. Sphaerotilus Bulking. Sludge bulking caused by the presence of the filament pus bacteria Sphaerotilus.